BKKDM - HMP (SN05PB94AG02) 366

  • MSDS: BKKDM
  • Manufacturer: MULTICORE SOLDERS INC
  • Product Name: HMP (SN05PB94AG02) 366
  • National Stock Number: 3439-00-411-7429
Product Identification

Product ID:HMP (SN05PB94AG02) 366
MSDS Date:02/20/1990
FSC:3439
NIIN:00-411-7429
MSDS Number: BKKDM

Responsible Party
MULTICORE SOLDERS, INC.
CANTIAGUE ROCK RD
WESTBURY, NY 11590
US

Emergency Phone: 214-238-1224

Info Phone: 516-334-7997

Cage: 03051

Contractor
MULTICORE SOLDERS
WESTBURY, NY 11590 US

Telephone: 214-238-1224

Cage: 03051

Ingredients

LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 90-95%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 4-6%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9192


SILVER (SARA III)

CAS: 7440-22-4

RTECS: VW3500000

Fraction By Weight: 1-2%

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.1 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ROSIN ACID

CAS: 8050-09-7

Fraction By Weight: 2-3%

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: WEAKNESS, VOMITING, LOSS OF
APPETITE, CONVULSIONS, STUPOR AND POSSIBLY COMA. CHRONIC: WEAKNESS,
INSOMNIA, HYPERTENSION, SLIGHT IRRITATION OF THE EYES, HEADACHE,
POSSIBLE PARALYSIS. CHRONIC OVER EXPOSURE TO LEAD MAY RESULT IN
DAMAGE TO BLOOD FORMING, NERVOUS, URINARY AND REPRODUCTIVE SYSTEM.
Explanation of Carcinogenicity:NOT LISTED BY NTP, IRAC OR OSHA AS A
CARCINOGEN.
Effects of Overexposure:DUST, VAPOR AND/OR FUMES MAY BE IRRITATING TO
SKIN, EYES, AND RESPIRATORY SYSTEM.
Medical Cond Aggravated by Exposure:DISEASES OF THE BLOOD-FORMING,
NERVOUS, URINARY AND REPRODUCTIVE SYSTEMS. EXPOSURE TO LEAD MAY
RESULT IN INJURY TO A DEVELOPING FETUS.

First Aid

First Aid:EYES: FLUSH WITH COPIOUS QUANTITIES OF WATER. GET IMMEDIATE
MEDICAL ATTENTION. SKIN: WASH WITH SOAP AND WATER. INHALATION:
REMOVE FROM EXPOSURE. GET MEDICAL ATTENTION IF EXPERIENCING EFFECT
OF OVEREXP OSURE. INGESTION: GET IMMEDIATE MEDICALATTENTION.

Fire Fighting

Extinguishing Media:USE CARBON DIOXIDE, FOAM, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. EVACUATE AREA. COOL
FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:DO NOT USE WATER ON FIRES WHERE MOLTEN
METAL IS PRESENT. HIGH TEMPERATURES MAY PRODUCE HEAVY METAL FUMES,
DUST AND/OR VAPOR.

Accidental Release

Spill Release Procedures:CLEAN UP BY VACUUMING TO MINIMIZE DUST
EXPOSURE. PROVIDE CLEAN UP EMPLOYEES WITH RESPIRATORS IF THE
POSSIBILITY FOR EXPOSURE TO DUST OR FUMES EXISTS.

Handling

Handling and Storage Precautions:WASH HANDS WITH SOAP AND WATER AFTER
HANDLING SOLDER.
Other Precautions:STORE IN DRY AREA. AVOID SKIN CONTACT. AVOID BRATHING
SMOKE DURING SOLDERING.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR LEAD, IF
EXPOSURES EXCEED THE OSHA LIMIT.
Ventilation:USE ENOUGH VENTILATION WHEN CUTTING OR GRINDING TO KEEP THE
DUST AND FUMES FROM THE WORKERS BREATHING ZONE & BELOW PEL.
Protective Gloves:IMPERVIOUS
Eye Protection:FACE SHIELD OR SAFETY GLASSES.
Other Protective Equipment:PERSONAL CLOTHIHG AND SHOES SHOULD BE
PROTECTED FORM CONTAMINATION. EYE WASH STATION.
Work Hygienic Practices:WASH THOROUGHLY BEFORE EATING OR SMOKING.
LAUNDER CONTAMINATIED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:565F,296C
Spec Gravity:11 @25 C
Solubility in Water:INSOLUBLE
Appearance and Odor:GRAY METAL WITH NEUTRAL ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HIGH TEMPERATURES MAY PRODUCE HEAVY
METAL FUMES, DUST AND/OR VAPORS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE &
LOCAL LAWS AND REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.